News

Check out the insights from the Echo Square Team. We are experts In our field and love to educate our visitors on our industry.

Water Storage Tank Replacement London

Water storage tank replacement recently completed at a prestigious university in central London. Our clients existing GRP sprinkler tank had failed due to the base of the storage tank completely giving way. Following a site visit by one of our specialist consultants it became apparent that the existing GRP storage tank was non-repairable by either carrying …

Read more

Water Tank Replacement London

New GRP water tank installation

Water tank replacement project recently completed in Mayfair, central London. The existing water storage tanks had completely failed ensuring they were impossible to refurbish or repair by carrying out a full tank reline. Almost all the water tanks joints had failed, including the butyl mastic between the panels in the dividing wall which subsequently caused …

Read more

GRP Tank Reline Cornwall

second coat of polyurethane

GRP tank reline recently completed in a leisure center in Cornwall. Our client required a sustainable solution to help repair their sites cold water storage tank. As the leisure centre’s facilities are in constant use, isolating the cold water services for a long period of time to complete a water tank repair wasn’t an option. …

Read more

Resin Injection Water Stop Works 

Resin injection

Resin injection project recently completed in Gatwick on the behalf of a national facilities management company. Our client contacted us with regards to a ground water leak which had occurred in their underground concrete plant room. Despite many in house attempts to stop the leak, the basement water leak persisted. Our trenchless solution involved our operatives …

Read more

Concrete Water Tank Reline Farringdon

concrete water tank reline

Concrete water tank reline and refurbishment recently completed in Farringdon, central London. The existing epoxy coating in both water storage tanks had began to delaminate and severely blister in numerous locations. These issues had been highlighted in a recently completed legionella risk assessment which deemed both water tanks to be non-compliant with ACOP L8 guidelines. …

Read more

GRP Water Tank Repair Warrington

GRP water tank reline

Echo Square Services recently completed the water tank repair and full refurbishment of a sectional GRP water storage tank in Warrington. The existing water tanks internal surfaces were beginning to delaminate and the majority of the mild steel fittings had corroded beyond repair. Due to the water storage tank being in constant use it wasn’t …

Read more

Concrete Tank Reline

Echo Square Services recently completed the full refurbishment and tank reline of a concrete rain water tank in Kensington, central London.  The existing concrete water tank was partially full of concrete and debris which required removal before any refurbishment works could go ahead. The pipe work leading into the tank was also partially blocked with …

Read more