News

Check out the insights from the Echo Square Team. We are experts In our field and love to educate our visitors on our industry.

Water Tank Repair & Reline in Hull

We recently received an urgent call from a Pharmaceutical company in Hull in regards to a cold water storage tank that they had been forced to take offline due to a small crack in the tanks base. The crack was unfortunately caused by a heavy sump pump which had been accidentally dropped whilst the tank …

Read more

Water Tank Repair & Reline in Scotland.

What an incredible project to be involved in! Echo Square Services were recommended by a consultant to assist in the full refurbishment and water tank relining of two failed GRP cold water storage tanks located in Stirling Castle. Not only did we carry out carry out the water tank relining works we also replaced all …

Read more

Galvanised Steel Cold Water Tank Reline in Cumbria

It’s a common misconception that all corroded cold water storage tanks should always be replaced. We recently internally prepared and relined this flat galvanised steel cold water storage tank in Cumbria following extensive preparation prior to applying our WRAS approved ES988 DWPU polyurethane coating. We also disinfected the cold water storage tank as required by …

Read more

GRP Water Tank Repair & Tank Reline in London

completed water tank Reline in London

GRP cold water storage tank Echo Square Services recently fully refurbished and relined in a hotel in London. The GRP cold water storage tank had been offline for a long period of time due to suffering from heavy delamination of the internal GRP substrate & multiple broken internal tie rods which had adversely affected the …

Read more

Chemical Bund Lining London

Relining of a chemical containment bund resistant to sulphuric acid spillages carried out in London. The original chemical containment vessel was leaking and required replacement therefore we were contracted to prepare and reline the existing containment bund with a sulphuric acid resistant lining, place the new vessel in the newly chemically bunded area and then …

Read more

Hollow Support Replacement

ACoP L8 legislation provided by the Health and Safety Executive indicates that hollow tank supports are no longer permitted in cold water storage tank installations. Echo Square provide a nationwide service where we can replace your sites cold water storage tanks hollow supports with solid WRAS approved roof supports to ensure your cold water storage tank …

Read more

Water Tank Clean & Disinfections

Echo Square are a leading specialist in the internal relining and refurbishment for all types of liquid storage tanks. We are also often asked to disinfect cold water storage tanks upon completion of our works before placing them back online to ensure compliancy with ACoP L8 guidelines. Below is a cold water storage tank we relined using ES 988 DWPU …

Read more

GRP Tank Relining Works in London

A common issue with GRP cold water storage tanks old and new is the growth of black spores beneath the GRP gel coat. In accordance with ACoP L8 HSG274 these black spores are deemed as non-compliant and must be removed. Simply cleaning the spores off a cold-water storage tanks internal surfaces only temporarily removes the …

Read more